Field evaluation for diagnostic accuracy of the rapid test SD Bioline Malaria Antigen Pf/Pv® in Colombia

Nohora Marcela Mendoza, Zulma Milena Cucunubá, Samanda Aponte, Nohora Elizabeth González, Sindy Durley Bernal, .

Abstract

Introduction: Rapid diagnostic tests (RDT) have been postulated as a way to ensure access to malaria diagnosis in remote areas. Despite its widespread use, there are no field studies to evaluate the accuracy of the SD Bioline Malaria Antigen Pf/Pv in Colombia RDT.

Objective: To evaluate the diagnostic accuracy of the SD Bioline Malaria Antigen Pf/Pv® RDT in two departments endemic for malaria, comparing diagnosis with thick film corrected with PCR.

Materials and methods: A retrospective study was carried out to evaluate sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), concordance and sensitivity limits according to parasitemia ranges for the SD Bioline Malaria Antigen Pf/Pv ® test in Cordoba and Choco. The results were compared with microscopy corrected by PCR.

Results: A total of 383 samples processed, 121 were positive (75 for P. vivax, 42 for P. falciparum and 4 for mixed infection) and 262 negative samples. P. vivax: sensitivity 92.0% (95% CI: 83.6-96.3), specificity 98.7% ( 95% CI: 96.7-99.5), PPV 94.5% (95% CI: 86.7-97.9), NPV 98.1% (95% CI: 95.8-99.1), Cohen’s kappa coefficient was 0.90 (0.80-1.00). P. falciparum: sensitivity 88.1% (95% CI: 75.0-94.8), specificity 97.9% (95% CI: 95.8-99.0), PPV 84.1% (95% CI: 70.6-92.1), NPV 98.5% (95% IC: 96.6-99.4), Cohen’s kappa coefficient 0.80 (95% CI: 0.70-0.90).

Conclusions: The test performed well, being better for P. vivax as compared to P. falciparum. There are still difficulties of RDT to detect low parasitemias. The non amplification of Pfhrp2 and Pfhrp3 genes in two samples diagnosed as mixed infection, suggest a possible deletion of these two genes together.

 

doi: http://dx.doi.org/10.7705/biomedica.v33i4.1464

Downloads

Download data is not yet available.
  • Nohora Marcela Mendoza Grupo de Parasitología, Instituto Nacional de Salud, Bogotá, D.C., Colombia
  • Zulma Milena Cucunubá Grupo de Parasitología, Instituto Nacional de Salud, Bogotá, D.C., Colombia
  • Samanda Aponte Grupo de Bioquímica, Instituto Nacional de Salud, Bogotá, D.C., Colombia
  • Nohora Elizabeth González Grupo de Parasitología, Instituto Nacional de Salud, Bogotá, D.C., Colombia
  • Sindy Durley Bernal Grupo de Bioquímica, Instituto Nacional de Salud, Bogotá, D.C., Colombia
How to Cite
1.
Mendoza NM, Cucunubá ZM, Aponte S, González NE, Bernal SD. Field evaluation for diagnostic accuracy of the rapid test SD Bioline Malaria Antigen Pf/Pv® in Colombia. biomedica [Internet]. 2013 Dec. 1 [cited 2024 May 16];33(4):587-97. Available from: https://revistabiomedica.org/index.php/biomedica/article/view/1464
Published
2013-12-01
Section
Original articles

Altmetric

Article metrics
Abstract views
Galley vies
PDF Views
HTML views
Other views
QR Code